Heating & AC Repair, Replacement and HVAC Contractor in Odenville AL
Perfect Service Heating & Air provides air conditioning, heating, and indoor air quality services to the residents of Odenville, AL and the surrounding areas! In business since 2002, we are proud to offer professional services from a local small business that will keep you and your family comfortable all year long!
Read our reviews below and find out why your neighbors consider us to be their top choice when it come to heating and air concerns in Odenville, AL. Our expert AC repairs, installation service and tune-ups are backed by incredible warranties and performed by NATE certified technicians. Connect with Perfect Service today for perfect service every time!
Recent Jobs and Reviews in Odenville, AL
Odenville, AL at a glance
Perfect Service Heating & Air has completed 25 jobs in Odenville, AL between December 2019 and September 2020.
The most recent job was on September 30, 2020.
Perfect Service Heating & Air has completed 113 jobs in Odenville, AL in the last 12 months. The first job there was in November 2015.
Our Local Reviews by City
- Acmar, AL (1)
- Adamsville, AL (34)
- Adger, AL (5)
- Alabaster, AL (99)
- Alpine, AL (1)
- Altoona, AL (4)
- Anniston, AL (1)
- Ashville, AL (33)
- Athens, AL (1)
- Attalla, AL (1)
- Bessemer, AL (106)
- Bessmer, AL (1)
- Bham, AL (2)
- Biirmingham, AL (2)
- Birmignham, AL (1)
- Birmingham, AL (1074)
- Birningham, AL (1)
- Bluff Park, AL (1)
- Bradford, AL (3)
- Breman, AL (1)
- Bremen, AL (1)
- Brierfield, AL (1)
- Brighton, AL (2)
- Brookwood, AL (1)
- Calera, AL (77)
- Center Point, AL (69)
- Centerpoint, AL (2)
- Chelsea, AL (60)
- Childersburg, AL (2)
- Clanton, AL (1)
- Clay, AL (2)
- Cleveland, AL (1)
- Coalburg, AL (3)
- Columbiana, AL (46)
- Cordova, AL (3)
- Cottondale, AL (1)
- Cropwell, AL (14)
- Cullman, AL (2)
- Dixiana, AL (2)
- Dolemite, AL (1)
- Dora, AL (17)
- Dyer, IN (1)
- Eastaboga, AL (1)
- Empire, AL (5)
- Ensley, AL (1)
- Fairfield, AL (54)
- Fultondale, AL (35)
- GADSDEN, AL (13)
- Gardendale, AL (72)
- Goodwater, AL (1)
- Graysville, AL (2)
- Gurley, AL (1)
- Hayden, AL (19)
- Helena, AL (57)
- Homewood, AL (6)
- Hoover, AL (51)
- Hueytown, AL (31)
- HUNTSVILLE, AL (4)
- Indian Springs Village, AL (1)
- Irondale, AL (115)
- Jasper, AL (3)
- Kimberly, AL (14)
- La Fayette, AL (2)
- Lake View, AL (4)
- Leeds, AL (55)
- Lincoln, AL (46)
- Locust Fork, AL (2)
- Madison, AL (2)
- Margaret, AL (3)
- Maylene, AL (1)
- McCalla, AL (42)
- Meridianville, AL (1)
- Midfield, AL (9)
- Montevallo, AL (44)
- Moody, AL (63)
- Morris, AL (16)
- Mount Olive, AL (34)
- Mountain, AL (1)
- Mountain Brook, AL (13)
- Mt Brook, AL (2)
- Mt Olive, AL (2)
- Mtn Brooke, AL (1)
- Mulga, AL (3)
- Odenville, AL (57)
- Oneonta, AL (8)
- Onteonta, AL (1)
- Owens Cross Roads, AL (2)
- Pelham, AL (93)
- Pell City, AL (74)
- Pinson, AL (123)
- Pleasant Grove, AL (35)
- Quinton, AL (4)
- Ragland, AL (12)
- Randolph, AL (2)
- Remlap, AL (24)
- Riverside, AL (10)
- Shelby, AL (2)
- Southside, AL (1)
- Springville, AL (82)
- Steele, AL (3)
- Sterrett, AL (21)
- SUMITON, AL (4)
- Sylvan Springs, AL (6)
- Talladega, AL (9)
- Tarrant, AL (1)
- Thorsby, AL (1)
- Trafford, AL (9)
- Trussville, AL (172)
- Tuscaloosa, AL (2)
- Vestavia, AL (5)
- Vestavia Hills, AL (91)
- Vincent, AL (33)
- Waldo, AL (1)
- Warrior, AL (57)
- Westover, AL (1)
- Wilsonville, AL (22)
Job Locations and Reviews
MAINTENANCE CHECK-UP PER SERVICE AGREEMENT FOR 13 YR AC/ UNIT/ GAS PK. INSTALL UV. NEW SERVICE AGREEMENT. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, DRAINAGE, FREON LEVELS, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS OPERATING GOOD.
MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR HT UNIT. NEW SERVICE AGREEMENT. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CLEAN AND CHECK BURNERS AND BURNER OPERATION, CHECK THERMOSTAT, AIR FILTER, AIRFLOW, CHECK HEAT EXCHANGER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. EVERYTHING IS OPERATING GOOD.
CAME OUT ON A SERVICE CALL. INSTALL 2T AND 2.5T XX'S A/H'S 12YR P&L. EARNED 2 UNIT SERVICE AGREEMENT. MADE SURE EQUIPMENT WAS INSTALLED CORRECTLY, AND WORK AREA WAS CLEAN WHEN FINISH. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, DRAINAGE, FREON LEVELS, BLOWER COMPONENTS, VOLTAGE, AND AMPERAGE ON MOTORS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS OPERATING GOOD.
2ND 13 POINT MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 8 YR A/C UNIT. RENEWED SERVICE AGREEMENT. CHECK THERMOSTAT, FREON LEVELS, DRAINAGE, AIRFLOW, AIR FILTER, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. EVERYTHING IS OPERATING GOOD.
MAINTENANCE TUNE-UP FOR 2 A/C UNITS, 15 AND 20 YR. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, DRAINAGE, FREON LEVELS, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS. AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GOOD.
CAME OUT ON SERVICE CALL, NO A/C. BAD CAP AND CONTACTOR. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GOOD.
FIRST 13 POINT MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 17 YR A/C UNIT. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. EVERYTHING IS RUNNING GREAT.
MAINTENANCE CHECK-UP FOR AIR CONDITION UNIT. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, CONDENSER COIL, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. INSTALLED 3T AC EVAP 12YR P&L. NEW SERVICE AGREEMENT TO HER AND NEW SA TO HER PAPPA. MADE SURE EQUIPMENT WAS INSTALLED CORRECTLY AND WORK WAS CLEAN WHEN FINISH. CHECK ENERGY CONSUMPTION AND DRAINAGE. EVERYTHING IS WORKING GOOD.
13 POINT MAINT. CHECK-UP FOR 9 YR AIR CONDITION UNIT. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS. CHECK VOLTAGE AND AMPERAGE ON MOTORS. CLEAN AND CHECK CONDENSER COIL. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GREAT.
MAINT. CHECK-UP FOR 15 YEAR AIR CONDITION SYSTEM. CHECK FREON LEVELS, DRAINAGE, THERMOSTAT, AIRFLOW, AIR FILTER, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. EVERYTHING I S GOOD.
1ST MAINT. CHECK-UP PER SERVICE AGREEMENT FOR 6 YEAR AIR CONDITION UNIT. ALGAE TABS. CHECK ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, FREON LEVELS, DRAINAGE, THERMOSTAT, AIRFLOW, AIR FILTER, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. EVERYTHING IS RUNNING FINE.
2ND MAINT. CHECK-UP UNDER SERVICE AGREEMENT FOR 2 YR A/C UNIT. RENEWED SERVICE AGREEMENT. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS WORKING GOOD.
CLEAN AND CHECK-UP FOR 13 YEAR AIR CONDITION UNIT. NEW SERVICE AGREEMENT. CHECK FREON LEVELS, THERMOSTAT, AIR FILTER, AIRFLOW, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. EVERYTHING IS GOING GOOD.
CLEAN AND CHECK 4 YR A/C UNIT. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GOOD.
SECOND MAINTENANCE TUNE-UP PER SERVICE AGREEMENT FOR 8 YR A/C UNIT. RENEWED SERVICE AGREEMENT. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS GOOD.
1 ST MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 11 YR A/C UNIT. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, DRAINAGE, FREON LEVELS, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. EVERYTHING IS GOOD.
FIRST MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 8 YR A/C UNIT. ADJUST BLOWER COMPONENTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. CHECK THERMOSTAT, FREON LEVELS, DRAINAGE, AIRFLOW, AIR FILTER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GOOD.
2ND MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 8 YR A/C UNIT. RENEWED SERVICE AGREEMENT. CHECK THERMOSTAT, COMPRESSOR DELAY SAFETY CONTROL, AIR FILTER, AIRFLOW, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. EVERYTHING IS RUNNING GREAT.
CAME OUT FOR ADC ESTIMATE. INSTALLED PREM ADC. MADE SURE SYSTEM WAS INSTALLED PROPERLY. MADE SURE WORK AREA WAS CLEAN WHEN FINISHED INSTALLATION. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, AND ALL ELECTRICAL CONNECTIONS. CHECK DUCTS. GAVE SERVICE AGREEMENT.
FIRST CLEAN AND CHECK UNDER SERVICE AGREEMENT FOR 10YR HEATING UNIT. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CHECK HEAT EXCHANGER, HIGH LIMIT CONTROL, THERMOSTAT, AIR FILTER, AIRFLOW, FAN CONTROL, ENERGY CONSUMPTION, HUMIDIFIER, AND ALL ELECTRICAL CONNECTIONS.
CLEAN AND CHECK 8YR HEATING SYSTEM. CLEAN AND CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS. CHECK HEAT EXCHANGER AND HIGH LIMIT CONTROL. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, FAN CONTROL, ENERGY CONSUMPTION, HUMIDIFIER, AND ALL ELECTRICAL CONNECTION.
13 POINT TUNE-UP FOR 13YR HEATING UNIT. CLEAN AND CHECK BURNERS AND BURNER. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, AIRFLOW, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. RENEWED SERVICE AGREEMENT.
10 YEAR HEATING UNIT. 2ND CLEAN AND CHECK UNDER SERVICE AGREEMENT. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, AIRFLOW, ENERGY CONSUMPTION, HEAT EXCHENGER, AND HIGH LIMIIT CONTROL. RENEWED SA.
2ND CLEAN AND CHECK FOR HEATING SYSTEM. CLEAN AND CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENTS, LUBRICATE ALL NECESSARY MOVING PARTS. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, HUMIDIFIER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS.
PERFORM A 13 POINT CHECK-UP ON HEATING UNIT. CHECK ALL ELECTRICAL CONNECTIONS, THERMOSTAT, AIR FILTER, HUMIDIFIER, HEAT EXCHANGER, HIGH LIMIT CONTROL, GAS PRESSURE AND FOR PROPER VENTING. CLEAN AND CHECK BURNERS AND BURNER OPERATION. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS.,