Since opening our doors in 2002, Perfect Service has provided exceptional and affordable heating and air services to the residents of Hueytown, AL. We offer friendly service along with knowledgeable professional work completed on ACs, heaters and more!
We invite you to read some of our reviews below and find out why your neighbors in Hueytown, AL continue to call us for their HVAC contractor needs. For your AC repairs, installations and maintenance concerns, connect with the team at Perfect Service today!
Local Reviews
for Hueytown, AL
Our Reviews by City
Pleasant
DIANE - Hueytown, AL
I want him as my service person every time !
Great service, very professional!
RICHARD - Hueytown, AL
Tech was very professional and ensured to have proper social distancing during this difficult time.
Yearly checkup on heating and air
MARIE - Hueytown, AL
Very courteous and efficient.
Great
DERRY - Hueytown, AL
Jeff was very through and professional
You need 2 give air Filter With the service
RILEY - Hueytown, AL
Good Service
Billy - Hueytown, AL
Nice young man!
Good service
MARK - Hueytown, AL
Good service
James - Hueytown, AL
Wonderful
Absolutely perfect service from them.
Doris - Hueytown, AL
Very thorough in checking unit. The nicest technician.
Excellent Service
Billy - Hueytown, AL
Birmingham’s Best
Great service
Richard - Hueytown, AL
Informative
Nicholas - Hueytown, AL
Good service! !!
BRIDGET - Hueytown, AL
The repairman seem to know his job and was very efficient. No complaints.

Jake F.
FIRST MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 5 YR A/C UNIT. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. CHECK AIRFLOW, AIR FILTER, THERMOSTAT, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS OPERATING GOOD.


Anthony B.
2ND MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 7 YR HT UNIT. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GREAT.


Buddy B.
FIRST MAINTENANCE CHECK-UP PER SERVICE AGREEMENT FOR 8 YR HT UNIT. INSTALLED 2.5 XX A/H 12 YR P&L PREM ADC. REME HALO #A2URHL11319 ENSA*CI9 SALE. WORK AREA WAS LEFT CLEAN AFTER UNIT WAS INSTALLED. CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS. CHECK BLOWER COMPONENTS. EVERYTHING IS OPERATING GOOD.


Kyle K.
2ND 13 POINT MAINT. TUNE-UP UNDER SERVICE AGREEMENT FOR 2 HT UNITS, 2 YR, AND 3YR. RENEWED SERVICE AGREEMENT. CLEAN AND CHECK BURNERS AND BURNER OPERATION. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, AIRFLOW, AIR FILTER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS, EVERYTHING IS RUNNING.


JEFF B.
CAME OUT ON A SERVICE CALL, NO AC. MULTI ISSUES, GROWTH. INSTALLED 3T HP FURNACE AND COIL, WITH UV. 12Y PNL. NEW SERVICE AGREEMENT. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, HEAT EXCHANGER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. CHECK VOLTAGE AND AMPERAGE ON MOTORS. EVERYTHING IS RUNNING GREAT.


Kyle K.
2ND MAINT. CHECK-UP UNDER SERVICE AGREEMENT FOR HEATING UNIT. RENEWED SERVICE AGREEMENT. UV STILL WORKING. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK AIRFLOW, AIR FILTER, THERMOSTAT, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS OPERATING GOOD.


David B.
MAINTENANCE CHECK-UP UNDER SERVICE AGREEMENT FOR 2 HT UNIT, 8 YR AND 12 YR. NEW SERVICE AGREEMENT. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK AIR FILTER, AIRFLOW, THERMOSTAT, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS OPERATING GOOD.


Team Perfect Service !.
1ST MAINT. TUNE-UP PER SERVICE AGREEMENT FOR 3 YR HT UNIT. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, THERMOSTAT, AIRFLOW, AIR FILTER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GREAT.


Andrew S.
1ST MAINTENANCE CHECK-UP UNDER SERVICE AGREEMENT FOR 9 YR HT UNIT. CLEAN AND CHECK BURNERS AND BURNER OPERATION, CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, THERMOSTAT, AIRFLOW AIR FILTER, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS OPERATNG GOOD.


David B.
13 POINT CLEAN AND CHECK PER SERVICE AGREEMENT FOR 4 YR HT UNIT. NEW SERVICE AGREEMENT. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CLEAN AND CHECK BURNERS AND BURNER OPERATION. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS CHECK THERMOSTAT, AIRFLOW, AIR FILTER, HEAT EXCHANGER, HIGH LIMIT CONTROL, FAN CONTROL, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS OPERATING GREAT.


Joey I.
P/R, INSTALL 3T XX /FURN/COIL, 10YR P&L. THE SYSTEMS WERE INSTALL CORRECTLY AND MADE SURE WORK AREA WAS CLEAN WHEN FINISH. CHECK BURNER OPERATION, HIGH LIMIT CONTROLS HEAT EXCHANGER, FAN CONTROL, CONDENSER COIL, BLOWER COMPONENTS, AND ALL ELECTRICAL CONNECTIONS. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, AND FOR PROPR ENERGY CONSUMPTION. EVERYTHING IS OPERATING GOOD.


David B.
FIRST 13 POINT MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 11 YR A/C UNIT. BLOWER MTR HAS HARD START. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIR FILTER, DRAINAGE, FREON LEVELS, AIRFLOW, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS. EVERYTHING IS GOING GOOD.


Brenden H.
MAINTENANCE TUNE-UP FOR 10 YEAR AIR CONDITION UNIT. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. EVERYTHING IS OPERATING GOOD.


Noah H.
FIRST 13 POINT MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 2 YR A/C UNIT. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. EVERYTHING IS RUNNING GOOD.


Brenden H.
FIRST CLEAN AND CHECK-UP PER SERVICE AGREEMENT FOR 9 YEAR AIR CONDITION UNIT. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROL, FREON LEVELS, DRAINAGE, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS. EVERYTHING IS RUNNING GOOD.


Buddy B.
CLEAN AND CHECK FOR 8 YEAR A/C UNIT. ONCE A YEAR SERVICE. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIRFLOW, AIR FILTER, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GREAT.


Hunter A.
CLEAN AND CHECK 8 YR A/C UNIT. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS, LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GREAT.


Brenden H.
SECOND MAINTENANCE TUNE-UP UNDER SERVICE AGREEMENT FOR 9 YR A/C UNIT. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, FREON LEVELS, DRAINAGE, COMPRESSOR DELAY SAFETY CONTROLS. ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. EVERYTHING IS RUNNING GOOD.


Jesse C.
MAINT. TUNE-UP FOR 10 YR A/C UNIT. ADJUST BLOWER COMPONENTS, AND LUBRICATE ALL NECESSARY MOVING PARTS. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS, CHECK THERMOSTAT, AIR FILTER, AIRFLOW, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GOOD.


Jesse C.
CLEAN AND CHECK A/C UNIT. CLEAN AND CHECK CONDENSER COIL. CHECK VOLTAGE AND AMPERAGE ON MOTORS. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, FREON LEVELS, DRAINAGE, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GOOD,


Terry F.
CLEAN AND CHECK HEAT UNIT. INSTALLED 12 YR PREM GAS PACK WITH UV. MADE SURE EQUIPMENT WAS INSTALLED PROPERLY AND WORK AREA WAS CLEAN WHEN FINISH. CHECK BURNERS AND BURNER OPERATION. CHECK HEAT HIGH LIMIT CONTROLS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, HUMIDIFIER, COMPRESSOR DELAY SAFETY CONTROLS, AND ALL ELECTRICAL CONNECTIONS, CHECK VOLTAGE AND AMPERAGE ON MOTORS. EVERYTHING IS RUNNING GREAT.


Andrew S.
CLEAN AND CHECK 10 YR HEATING UNIT. CLEAN AND CHECK BURNERS AND BURNER OPERATION, LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS. CHECK HEAT HIGH LIMIT CONTROL. CHECK THERMOSTAT, HUMIDIFIER, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, COMPRESSOR DELAY SAFETY CONTROL. AND ALL ELECTRICAL CONNECTIONS. EVERYTHING IS RUNNING GREAT.


Andrew S.
CLEAN AND CHECK 1YR AIR CONDITION UNIT. CLEAN AND CHECK CONDENSER COIL. CHECK COMPRESSOR DELAY SAFETY CONTROLS. CHECK VOLTAGE AND AMPERAGE ON MOTORS. ADJUST BLOWER COMPONENTS AND LUBRICATE ALL NECESSARY MOVING PARTS. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, FREON LEVELS, DRAINAGE, AND ALL ELECTRICAL CONNECTIONS.


Scott H.
CLEAN AND CHECK HEATING UNIT. DNS SERVICE AGREEMENT. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK HEAT EXCHANGER AND HIGH LIMIT CONTROL. LUBRICATE ALL NECESSARY MOVING PARTS, AND ADJUST BLOWER COMPONENTS. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. CHECK THERMOSTAT, AIR FILTER, HUMIDIFIER, AIRFLOW, ENERGY CONSUMPTION, FAN CONTROL, AND ALL ELECTRICAL CONNECTIONS.


Andrew S.
CLEAN AND CHECK 7YR HEATING SYSTEM. CHECK THERMOSTAT, AIR FILTER, AIRFLOW, ENERGY CONSUMPTION, HEAT EXCHANGER, HIGH LIMIT CONTROL, HUMIDIFIER, AND ALL ELECTRICAL CONNECTIONS. CLEAN AND CHECK BURNERS AND BURNER OPERATION. CHECK MANIFOLD GAS PRESSURE AND FOR PROPER VENTING. LUBRICATE ALL NECESSARY MOVING PARTS AND ADJUST BLOWER COMPONENTS.